Seminar / Kurs

SINAMICS S120 - Parameterizing and Commissioning in TIA Portal (Face-to-face Training) in Erlangen

Inhalte

Inhalt
  • Design and functional principle of the converter system SINAMICS S120:
  • Control unit, line infeed and motor modules
  • Motors, encoders and interfaces
  • Parameterization, data backup and diagnostics using Software Startdrive in the TIA Portal:
  • Online connection via PROFINET and Ethernet
  • Project structure: drive objects and drive components
  • Topology of the DRIVE-CLiQ-Interface
  • Function charts: setpoint channel, Input and output signals
  • Control signals and internal signal interconnection using BiCo-technology
  • Optimization of the closed loop control using automatic procedures
  • Functional principle of the operating modes Servo and Vector
  • Analysis of the operating status using enable signals, warnings and alarms
  • Monitoring of signals using the trace function
  • Introduction to positioning and Safety Integrated
  • Data exchange with SIMATIC S7 via PROFINET using PROFIdrive Standard Telegram
  • Practical exercises at training kits with SINAMICS S120 in frame size booksize with servomotor and induction motor
Lernziele
  • You are responsible for the commissioning of SINAMICS S120 drive systems using the commissioning software Startdrive in TIA Portal.
  • Modern converter systems offer a variety of functions and setting possibilities. By a purposeful procedure you can save time and avoid faults.
  • In this course you will learn the procedure at commissioning step by step. You can handle parameter setting and data saving with the software Startdrive in the TIA Portal. By a correct parameter setting you support the reliable operation of the entire plant.
  • After the course you can put the converter system SINAMICS S120 efficiently into operation. You can adapt the parameters of the closed-loop controller to the respective application and use the diagnostic tools in case of a fault.
Zielgruppe
  • Commissioning Engineers
Inhalt
  • Design and functional principle of the converter system SINAMICS S120:
  • Control unit, line infeed and motor modules
  • Motors, encoders and interfaces
  • Parameterization, data backup and diagnostics u...
Mehr Informationen

Termine und Orte

Datum Dauer Preis
Erlangen, DE
14.09.2026 - 18.09.2026 40 h 40 h Details Details Jetzt buchen

+++ Catalog API +++

SG-Seminar-Nr.: 8766672

Anbieter-Seminar-Nr.: DE_DR-S12-PMT-E

Termin

14.09.2026 - 18.09.2026

Siemens AG
Siemenspromenade 18
91058 Erlangen

Durchführung garantiert. Der Seminaranbieter garantiert die Durchführung der Veranstaltung!

Günstige Preise

Semigator berücksichtigt

  • Frühbucher-Preise
  • Last-Minute-Preise
  • Gruppenkonditionen

€ 4.730,25

Alle Preise inkl. 19% MwSt.

Jetzt buchen
Seminar merken

Der Anbieter ist für den Inhalt verantwortlich.

Veranstaltungsinformation

  • Seminar / Kurs
  • Englisch
    • Keine
  • 40 h
  • Anbieterbewertung   (197)

Ihre Vorteile

mehr erfahren
  • Anbietervergleich von über 1.500 Seminaranbietern
  • Vollständige Veranstaltungsinformationen
  • Schnellbuchung
  • Persönlicher Service
Datum Dauer Preis
Erlangen, DE
14.09.2026 - 18.09.2026 40 h 40 h Details Details Jetzt buchen